title: "Our Work | Heat Pump Projects Hampshire | Appian"
description: "Real heat pump and air conditioning projects across Hampshire, Berkshire and Surrey — installations, repairs and optimisation case studies with photos."
lang: en-GB
json-ld: |
  {
    "@context": "https://schema.org",
    "@type": "BreadcrumbList",
    "itemListElement": [
      {
        "@type": "ListItem",
        "position": 1,
        "name": "Home",
        "item": "https://www.appianheatpumps.com/"
      },
      {
        "@type": "ListItem",
        "position": 2,
        "name": "Our Work"
      }
    ]
  }
---

[

Special Offer Air Conditioning Fully Installed from £1,100 →

](/contact)

12 Appian Way, Chineham, Basingstoke, RG24 8BH 

Fastest reply → [07481 552059](tel:07481552059)| [01256 672332](tel:01256672332)

[![Appian Heat Pumps](/assets/logo-DXHDe5EY.png)](/)

Services

Service Areas

[About](/about)[Our Work](/our-work)[Blog](/blog)[Reviews](/reviews)[Contact](/contact)

Call now — fastest reply [07481 552059](tel:07481552059)[Landline: 01256 672332](tel:01256672332)

[Request Estimate](/contact)

[Call 07481 552059 Fastest reply ](tel:07481552059)[Get Estimate](/contact)

![Air source heat pump unit mounted on a property exterior — Our Work](/assets/work-41-C99vEJNK.jpeg)

1.  [Home](/)

Our Work 

# Real Projects.   
Real Results. 

Every job tells a story. Here are some of the heat pump and air conditioning challenges we've solved for customers across Hampshire and beyond.

[Discuss Your Project](/contact)

![REFCOM F-Gas certified badge for heat pump engineers](/assets/refcom-badge-Bo6YwTLs.png)![Mitsubishi Electric accredited heat pump installer badge](/assets/mitsubishi-badge-e1lhTUMA.jpg)![Ecodan renewable heating technology accreditation badge](/assets/ecodan-badge-DKEvMTX0.jpg)

## Our Work in Pictures

Browse real heat pump installations, air conditioning repairs, and servicing work completed by Appian Heat Pumps across Hampshire, Berkshire, Surrey and Wiltshire.

![Mitsubishi Ecodan air source heat pump installed on concrete plinth outside a residential property in Hampshire](/assets/work-1-yCIVMH7-.jpeg)

![Split air conditioning outdoor condenser unit mounted on wall brackets at a domestic property](/assets/work-2-BWDRpBxC.jpeg)

![Completed heat pump installation showing outdoor unit with neatly routed pipework and electrical connections](/assets/work-3-B5RieGsd.jpeg)

![Air source heat pump positioned in rear garden with anti-vibration mounts and condensate drain](/assets/work-4-B-xosteY.jpeg)

![Domestic air conditioning wall-mounted indoor unit installed in a living room](/assets/work-4-B-xosteY.jpeg)

![Multi-split outdoor air conditioning unit serving multiple indoor zones at a Hampshire home](/assets/work-6-BtOxm4y4.jpeg)

![Ceiling cassette air conditioning unit installed flush in suspended ceiling of a commercial office](/assets/work-7-D0nsJOwO.jpeg)

![Heat pump plant room with hot water cylinder, buffer tank, and hydraulic connections](/assets/work-8-CLlbe1Wp.jpeg)

![Copper refrigerant pipework brazed and insulated during heat pump installation](/assets/work-9-D0pWt5DT.jpeg)

![Wall-mounted air conditioning unit installed above doorway in a residential bedroom](/assets/work-10-iRjiTVwx.jpeg)

![Mitsubishi Electric outdoor unit installed on a flat roof with weather protection](/assets/work-11-C0PjuPnq.jpeg)

![Air source heat pump system pipework entering property through external wall with sealed penetration](/assets/work-3-B5RieGsd.jpeg)

![New heat pump hot water cylinder installed in utility cupboard with pipework connections](/assets/work-13-Czi6KlAr.jpeg)

![Completed domestic air conditioning installation with trunking neatly routed along wall](/assets/work-14-Cd5-OU0o.jpeg)

![Heat pump outdoor unit installed in side passage with correct clearance distances maintained](/assets/work-15-CgZVHabU.jpeg)

![Commercial air conditioning condensing units installed on rooftop with vibration isolation](/assets/work-15-CgZVHabU.jpeg)

Show all 86 photos

## Detailed Case Studies

### Ecodan Heat Pump Installation — Detached Home, Basingstoke

#### The Challenge

A 4-bedroom detached property running an ageing oil boiler with annual fuel costs exceeding £3,200. The homeowners wanted a renewable heating solution but had been told by two other companies that their property wasn't suitable for a heat pump.

#### Our Solution

We conducted a full heat loss survey and designed a Mitsubishi Ecodan 11.2kW system with appropriately sized buffer tank and optimised flow temperatures. Existing radiators were assessed — only two required upsizing. The installation was completed in three days with minimal disruption.

#### The Result

Annual heating costs reduced to approximately £1,400. The system achieved a measured SCOP of 3.2 in its first winter. The homeowners reported consistently comfortable temperatures throughout the house for the first time in years.

[Learn more about Heat Pump Installation](/services/heat-pump-installation)

### Complex Fault Diagnosis — Daikin ASHP, Winchester

#### The Challenge

A 2-year-old Daikin Altherma system experiencing intermittent shutdowns. The original installer had attended three times, replacing the PCB and an expansion valve, but the fault persisted. The homeowner was left without heating for extended periods during winter.

#### Our Solution

Our diagnostic process identified a subtle refrigerant undercharge combined with an incorrectly positioned outdoor temperature sensor. The sensor was reading artificially high temperatures due to its proximity to an extract vent, causing the system to modulate incorrectly and trigger high-pressure faults.

#### The Result

Refrigerant charge corrected to manufacturer specification and sensor relocated to a compliant position. The system has run continuously without a single fault code in the 14 months since our intervention.

[Learn more about Heat Pump Repair](/services/heat-pump-repair)

### Commercial Multi-Split AC — Office Building, Guildford

#### The Challenge

A 6-unit office building with individual tenants requiring independent climate control. The existing system was a 15-year-old single-zone unit that couldn't meet varying demands across floors, leading to constant complaints and tenant dissatisfaction.

#### Our Solution

Designed and installed a Mitsubishi Electric City Multi VRF system with individual zone controllers for each office. The installation was phased over two weekends to avoid business disruption. Each tenant now has independent temperature control via wall-mounted controllers.

#### The Result

Tenant satisfaction improved significantly. Energy consumption reduced by approximately 35% compared to the previous system due to inverter-driven compressor technology and zone-specific control. No further complaints in the 18 months since installation.

[Learn more about Commercial Air Conditioning](/services/commercial-air-conditioning)

### Swimming Pool Heat Pump Recovery — Private Pool, Newbury

#### The Challenge

A 12m outdoor swimming pool with a failing heat pump that couldn't maintain temperature above 22°C even in summer. The pool was effectively unusable from September to May. Previous attempts at repair by a general plumber had been unsuccessful.

#### Our Solution

Diagnosed a significant refrigerant leak at the evaporator coil, compounded by a partially blocked plate heat exchanger caused by inadequate water treatment. We replaced the evaporator coil, recharged the system, and cleaned the heat exchanger. We also installed a water treatment system to prevent recurrence.

#### The Result

Pool temperature now maintained at 28°C consistently. The swimming season extended from May through October. The homeowner estimated they recouped the repair cost within four months compared to the quote they'd received for a full replacement unit.

[Learn more about Pool Heat Pump Repair](/services/swimming-pool-heat-pump-repair)

### System Optimisation — Underperforming ASHP, Reading

#### The Challenge

A Vaillant Arotherm heat pump installed 18 months earlier was producing heating bills nearly as high as the old gas boiler it replaced. The homeowner was frustrated and considering reverting to gas. The original installer insisted the system was working correctly.

#### Our Solution

Our health check revealed flow temperatures set 12°C higher than necessary, weather compensation curve misconfigured, and the buffer tank bypass valve stuck open — meaning the system was cycling constantly. We recalibrated the entire system, adjusted flow temperatures, corrected the weather compensation settings, and freed the bypass valve.

#### The Result

Monthly electricity consumption for heating dropped by 40% within the first billing cycle. The measured COP improved from 1.8 to 3.1. The homeowner now pays significantly less than they did with gas heating.

[Learn more about Commissioning & Optimisation](/services/commissioning-optimisation)

### Emergency Compressor Failure — Care Home, Farnborough

#### The Challenge

A residential care home's primary heating system — a Mitsubishi Ecodan cascade — suffered a compressor failure on a Friday evening in January. With vulnerable residents and sub-zero temperatures forecast, the situation was urgent.

#### Our Solution

We responded within 45 minutes. On-site diagnosis confirmed a seized compressor on the lead unit. We isolated the failed unit and reconfigured the cascade to run on the backup compressor at increased capacity while sourcing an emergency replacement. The new compressor was installed within 36 hours.

#### The Result

Internal temperatures never dropped below 19°C during the repair period. The care home manager reported that residents experienced no discomfort. The cascade system was fully restored to dual-compressor operation by Monday morning.

[Learn more about Emergency Repairs](/services/emergency-repairs)

## Have a Similar Challenge?

Whether it's a complex fault, a new [heat pump installation](/services/heat-pump-installation), or a system that's not performing — we've likely solved it before. Let's talk.

[Request a Free Estimate](/contact) [Call 07481 552059](tel:07481552059)

![Appian Heat Pumps](/assets/logo-DXHDe5EY.png)

Expert heat pump installation, repair & servicing across Hampshire and surrounding areas. Over 15 years of trusted experience.

[](https://www.linkedin.com/company/appian-heat-pumps/)[](https://www.facebook.com/profile.php?id=100091962078515)[](https://www.instagram.com/appian_heat_pumps)

### Services

-   [Heat Pump Repair](/services/heat-pump-repair)
-   [Heat Pump Servicing](/services/heat-pump-servicing)
-   [Heat Pump Installation](/services/heat-pump-installation)
-   [Air Conditioning Installation](/services/air-conditioning-installation)
-   [Commercial Air Conditioning](/services/commercial-air-conditioning)
-   [Pool Heat Pump Repair](/services/swimming-pool-heat-pump-repair)
-   [Pool Heat Pump Service](/services/swimming-pool-heat-pump-service)
-   [Pool Heat Pump Supply](/services/swimming-pool-heat-pump-supplier)
-   [Commissioning & Optimisation](/services/commissioning-optimisation)
-   [Emergency Repairs](/services/emergency-repairs)
-   [System Upgrades](/services/system-upgrades-retrofits)
-   [Smart Thermostat Integration](/services/smart-thermostat-integration)
-   [Health Checks](/services/health-checks)
-   [F-Gas AC Servicing](/services/fgas-air-conditioning-servicing)
-   [Maintenance Contracts](/services/annual-maintenance-contracts)

### Service Areas

-   [Basingstoke](/areas/basingstoke)
-   [Hampshire](/areas/hampshire)
-   [Berkshire](/areas/berkshire)
-   [Surrey](/areas/surrey)
-   [Wiltshire](/areas/wiltshire)
-   [Reading](/areas/reading)
-   [Winchester](/areas/winchester)
-   [Newbury](/areas/newbury)
-   [Guildford](/areas/guildford)
-   [Farnborough](/areas/farnborough)
-   [Aldershot](/areas/aldershot)
-   [Woking](/areas/woking)
-   [Basingstoke & Deane](/areas/basingstoke-and-deane)
-   [Andover](/areas/andover)
-   [Bracknell](/areas/bracknell)

### Company

-   [About](/about)
-   [Our Work](/our-work)
-   [Blog](/blog)
-   [Reviews](/reviews)
-   [Specials](/specials)
-   [Contact](/contact)
-   [Privacy Policy](/privacy-policy)
-   [Terms & Conditions](/terms-conditions)
-   [Cookie Policy](/cookie-policy)

### Contact Us

-   12 Appian Way, Chineham,  
    Basingstoke, RG24 8BH 
-   [07481 552059](tel:07481552059)Mobile — fastest reply; 24/7 for emergencies 
-   [Or landline: 01256 672332](tel:01256672332)
-   [info@appianheatpumps.com](mailto:info@appianheatpumps.com)
-   Opening Hours
    
    Mon–Fri: 7:00am – 7:00pm
    
    Sat: 8:00am – 5:00pm
    
    Sun: 9:00am – 1:00pm
    
    Emergency callout line: answered 24/7
    

© 2026 Appian Heat Pumps. All rights reserved.

VAT No: 476667534

We use essential cookies to run this site and analytics cookies to improve it. See our [Cookie Policy](/cookie-policy).

AcceptReject